This patch includes the implementation of the clock gating
for System MMU. Initially, all System MMUs are not asserted
the system clock. Asserting the system clock to a System MMU
is enabled only when s5p_sysmmu_enable() is called. Likewise,
it is disabled only when s5p_sysmmu_disable() is called.
Therefore, clock gating on System MMUs are still invisible to
the outside of the System MMU driver.
Signed-off-by: KyongHo Cho <pullip.cho@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>