Commit graph

18 commits

Author SHA1 Message Date
Sage Weil
457712a0bc ceph: return EIO on invalid layout on GET_DATALOC ioctl
If the user calls GET_DATALOC on a file with an invalid (e.g.,
zeroed) layout, return EIO to userland.

Signed-off-by: Sage Weil <sage@inktank.com>
Reviewed-by: Alex Elder <elder@inktank.com>
2012-10-03 10:51:17 -05:00
Sage Weil
45f2e081f5 ceph: avoid divide by zero in __validate_layout()
If "l->stripe_unit" is zero the the mod on the next line will cause a
divide by zero bug.  This comes from the copy_from_user() in
ceph_ioctl_set_layout_policy().  Passing 0 is valid, though (it means
"do not change") so avoid the % check in that case.

Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Sage Weil <sage@inktank.com>
Reviewed-by: Alex Elder <elder@inktank.com>
2012-08-21 15:55:28 -07:00
Sage Weil
c047be0934 ceph: ignore preferred_osd field
Old users may not expect EINVAL, and there is no clear user-visibile
behavior change now that we ignore it.

Signed-off-by: Sage Weil <sage@inktank.com>
Reviewed-by: Alex Elder <elder@inktank.com>
2012-05-16 14:28:28 -05:00
Sage Weil
702aeb1f88 ceph: fully initialize new layout
When we are setting a new layout, fully initialize the structure:
 - zero it out
 - always set preferred_osd to -1

Signed-off-by: Sage Weil <sage@inktank.com>
Reviewed-by: Alex Elder <elder@inktank.com>
2012-05-16 14:28:27 -05:00
Sage Weil
e49bf4c51c ceph: refactor SETLAYOUT and SETDIRLAYOUT ioctl checks into common helper
Both of these methods perform similar checks; move that code to a helper
so that we can ensure the checks are consistent.

Reviewed-by: Alex Elder <elder@inktank.com>
Signed-off-by: Sage Weil <sage@inktank.com>
2012-05-07 15:34:35 -07:00
Sage Weil
3469ac1aa3 ceph: drop support for preferred_osd pgs
This was an ill-conceived feature that has been removed from Ceph.  Do
this gracefully:

 - reject attempts to specify a preferred_osd via the ioctl
 - stop exposing this information via virtual xattrs
 - always fill in -1 for requests, in case we talk to an older server
 - don't calculate preferred_osd placements/pgids

Reviewed-by: Alex Elder <elder@inktank.com>
Signed-off-by: Sage Weil <sage@inktank.com>
2012-05-07 15:33:36 -07:00
Sage Weil
be655596b3 ceph: use i_ceph_lock instead of i_lock
We have been using i_lock to protect all kinds of data structures in the
ceph_inode_info struct, including lists of inodes that we need to iterate
over while avoiding races with inode destruction.  That requires grabbing
a reference to the inode with the list lock protected, but igrab() now
takes i_lock to check the inode flags.

Changing the list lock ordering would be a painful process.

However, using a ceph-specific i_ceph_lock in the ceph inode instead of
i_lock is a simple mechanical change and avoids the ordering constraints
imposed by igrab().

Reported-by: Amon Ott <a.ott@m-privacy.de>
Signed-off-by: Sage Weil <sage@newdream.net>
2011-12-07 10:46:44 -08:00
Greg Farnum
a35eca958a ceph: let the set_layout ioctl set single traits
Previously we were validating the passed-in stripe unit, object size,
and stripe count against each other (and not testing most other stuff).
Instead, make sure that the composed previous layout and new values are valid,
and only send the new values to the MDS. This lets users change the
pool without setting the whole layout, for instance.

Signed-off-by: Greg Farnum <gregory.farnum@dreamhost.com>
2011-10-25 16:10:16 -07:00
Sage Weil
5f21c96dd5 ceph: protect access to d_parent
d_parent is protected by d_lock: use it when looking up a dentry's parent
directory inode.  Also take a reference and drop it in the caller to avoid
a use-after-free.

Reported-by: Al Viro <viro@ZenIV.linux.org.uk>
Reviewed-by: Yehuda Sadeh <yehuda@hq.newdream.net>
Signed-off-by: Sage Weil <sage@newdream.net>
2011-07-26 11:30:29 -07:00
Sage Weil
4918b6d140 ceph: add F_SYNC file flag to force sync (non-O_DIRECT) io
This allows us to force IO through the sync path which you normally only
get when multiple clients are reading/writing to the same file or by
mounting with -o sync.  Among other things, this lets test programs verify
correctness with a single mount.

Reviewed-by: Yehuda Sadeh <yehuda@hq.newdream.net>
Signed-off-by: Sage Weil <sage@newdream.net>
2011-07-26 11:26:07 -07:00
Sage Weil
70b666c3b4 ceph: use ihold when we already have an inode ref
We should use ihold whenever we already have a stable inode ref, even
when we aren't holding i_lock.  This avoids adding new and unnecessary
locking dependencies.

Signed-off-by: Sage Weil <sage@newdream.net>
2011-06-07 21:34:11 -07:00
Greg Farnum
571dba52a3 ceph: add CEPH_MDS_OP_SETDIRLAYOUT and associated ioctl.
Signed-off-by: Sage Weil <sage@newdream.net>
2010-10-20 15:38:23 -07:00
Yehuda Sadeh
3d14c5d2b6 ceph: factor out libceph from Ceph file system
This factors out protocol and low-level storage parts of ceph into a
separate libceph module living in net/ceph and include/linux/ceph.  This
is mostly a matter of moving files around.  However, a few key pieces
of the interface change as well:

 - ceph_client becomes ceph_fs_client and ceph_client, where the latter
   captures the mon and osd clients, and the fs_client gets the mds client
   and file system specific pieces.
 - Mount option parsing and debugfs setup is correspondingly broken into
   two pieces.
 - The mon client gets a generic handler callback for otherwise unknown
   messages (mds map, in this case).
 - The basic supported/required feature bits can be expanded (and are by
   ceph_fs_client).

No functional change, aside from some subtle error handling cases that got
cleaned up in the refactoring process.

Signed-off-by: Sage Weil <sage@newdream.net>
2010-10-20 15:37:28 -07:00
Sage Weil
8c6e9229fc ceph: add LAZYIO ioctl to mark a file description for lazy consistency
Allow an application to mark a file descriptor for lazy file consistency
semantics, allowing buffered reads and writes when multiple clients are
accessing the same file.

Signed-off-by: Sage Weil <sage@newdream.net>
2010-08-01 20:11:39 -07:00
Cheng Renquan
640ef79d27 ceph: use ceph_sb_to_client instead of ceph_client
ceph_sb_to_client and ceph_client are really identical, we need to dump
one; while function ceph_client is confusing with "struct ceph_client",
ceph_sb_to_client's definition is more clear; so we'd better switch all
call to ceph_sb_to_client.

  -static inline struct ceph_client *ceph_client(struct super_block *sb)
  -{
  -	return sb->s_fs_info;
  -}

Signed-off-by: Cheng Renquan <crquan@gmail.com>
Signed-off-by: Sage Weil <sage@newdream.net>
2010-05-17 15:25:17 -07:00
Sage Weil
33d4909ccc ceph: allow preferred osd to be get/set via layout ioctl
There is certainly no reason not to report this.

The only real downside to allowing the user to set it is that you don't
get default values by zeroing the layout struct (the default is -1).

Signed-off-by: Sage Weil <sage@newdream.net>
2009-12-03 14:59:48 -08:00
Sage Weil
51042122d4 ceph: fix endian conversions for ceph_pg
The endian conversions don't quite work with the old union ceph_pg.  Just
make it a regular struct, and make each field __le.  This is simpler and it
has the added bonus of actually working.

Signed-off-by: Sage Weil <sage@newdream.net>
2009-11-04 16:36:07 -08:00
Sage Weil
8f4e91dee2 ceph: ioctls
A few Ceph ioctls for getting and setting file layout (striping)
parameters, and learning the identity and network address of the OSD a
given region of a file is stored on.

Signed-off-by: Sage Weil <sage@newdream.net>
2009-10-06 11:31:14 -07:00