Commit Graph

7 Commits (a10d206ef1a83121ab7430cb196e0376a7145b22)

Author SHA1 Message Date
Jan Beulich 402c5e15b4 xen/pciback: miscellaneous adjustments
This is a minor bugfix and a set of small cleanups; as it is not clear
whether this needs splitting into pieces (and if so, at what
granularity), it is a single combined patch.
- add a missing return statement to an error path in
  kill_domain_by_device()
- use pci_is_enabled() rather than raw atomic_read()
- remove a bogus attempt to zero-terminate an already zero-terminated
  string
- #define DRV_NAME once uniformly in the shared local header
- make DRIVER_ATTR() variables static
- eliminate a pointless use of list_for_each_entry_safe()
- add MODULE_ALIAS()
- a little bit of constification
- adjust a few messages
- remove stray semicolons from inline function definitions

Signed-off-by: Jan Beulich <jbeulich@suse.com>
[v1: Dropped the resource_size fix, altered the description]
[v2: Fixed cleanpatch.pl comments]
Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
2011-09-21 18:17:59 -04:00
Thomas Meyer 5fa99911a3 xen/pciback: use resource_size()
Use resource_size function on resource object
 instead of explicit computation.

 The semantic patch that makes this output is available
 in scripts/coccinelle/api/resource_size.cocci.

 More information about semantic patching is available at
 http://coccinelle.lip6.fr/

Signed-off-by: Thomas Meyer <thomas@m3y3r.de>
Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
2011-09-21 16:21:42 -04:00
Konrad Rzeszutek Wilk a92336a117 xen/pciback: Drop two backends, squash and cleanup some code.
- Remove the slot and controller controller backend as they
   are not used.
 - Document the find pciback_[read|write]_config_[byte|word|dword]
   to make it easier to find.
 - Collapse the code from conf_space_capability_msi into pciback_ops.c
 - Collapse conf_space_capability_[pm|vpd].c in conf_space_capability.c
   [and remove the conf_space_capability.h file]
 - Rename all visible functions from pciback to xen_pcibk.
 - Rename all the printk/pr_info, etc that use the "pciback" to say
   "xen-pciback".
 - Convert functions that are not referenced outside the code to be
   static to save on name space.
 - Do the same thing for structures that are internal to the driver.
 - Run checkpatch.pl after the renames and fixup its warnings and
   fix any compile errors caused by the variable rename
 - Cleanup any structs that checkpath.pl commented about or just
   look odd.

Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
2011-07-19 20:58:35 -04:00
Konrad Rzeszutek Wilk 0513fe9e5b xen/pciback: Allocate IRQ handler for device that is shared with guest.
If the device that is to be shared with a guest is a level device and
the IRQ is shared with the initial domain we need to take actions.
Mainly we install a dummy IRQ handler that will ACK on the interrupt
line so as to not have the initial domain disable the interrupt line.

This dummy IRQ handler is not enabled when the device MSI/MSI-X lines
are set, nor for edge interrupts. And also not for level interrupts
that are not shared amongst devices. Lastly, if the user passes
to the guest all of the PCI devices on the shared line the we won't
install the dummy handler either.

There is also SysFS instrumentation to check its state and turn
IRQ ACKing on/off if necessary.

Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
2011-07-19 20:58:31 -04:00
Zhao, Yu fd5b221b34 xen/pciback: guest SR-IOV support for PV guest
These changes are for PV guest to use Virtual Function. Because the VF's
vendor, device registers in cfg space are 0xffff, which are invalid and
ignored by PCI device scan. Values in 'struct pci_dev' are fixed up by
SR-IOV code, and using these values will present correct VID and DID to
PV guest kernel.

And command registers in the cfg space are read only 0, which means we
have to emulate MMIO enable bit (VF only uses MMIO  resource) so PV
kernel can work properly.

Acked-by: Jan Beulich <jbeulich@novell.com>
Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
2011-07-19 20:58:30 -04:00
Konrad Rzeszutek Wilk 8bfd4e023f xen/pciback: Cleanup the driver based on checkpatch warnings and errors.
Checkpatch found some extra warnings and errors. This mega
patch fixes them all in one big swoop. We also spruce
up the pcistub_ids to use DEFINE_PCI_DEVICE_TABLE macro
(suggested by Jan Beulich).

Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
2011-07-19 20:58:28 -04:00
Konrad Rzeszutek Wilk 30edc14bf3 xen/pciback: xen pci backend driver.
This is the host side counterpart to the frontend driver in
drivers/pci/xen-pcifront.c. The PV protocol is also implemented by
frontend drivers in other OSes too, such as the BSDs.

The PV protocol is rather simple. There is page shared with the guest,
which has the 'struct xen_pci_sharedinfo' embossed in it. The backend
has a thread that is kicked every-time the structure is changed and
based on the operation field it performs specific tasks:

 XEN_PCI_OP_conf_[read|write]:
   Read/Write 0xCF8/0xCFC filtered data. (conf_space*.c)
   Based on which field is probed, we either enable/disable the PCI
   device, change power state, read VPD, etc. The major goal of this
   call is to provide a Physical IRQ (PIRQ) to the guest.

   The PIRQ is Xen hypervisor global IRQ value irrespective of the IRQ
   is tied in to the IO-APIC, or is a vector. For GSI type
   interrupts, the PIRQ==GSI holds. For MSI/MSI-X the
   PIRQ value != Linux IRQ number (thought PIRQ==vector).

   Please note, that with Xen, all interrupts (except those level shared ones)
   are injected directly to the guest - there is no host interaction.

 XEN_PCI_OP_[enable|disable]_msi[|x] (pciback_ops.c)
   Enables/disables the MSI/MSI-X capability of the device. These operations
   setup the MSI/MSI-X vectors for the guest and pass them to the frontend.

   When the device is activated, the interrupts are directly injected in the
   guest without involving the host.

 XEN_PCI_OP_aer_[detected|resume|mmio|slotreset]: In case of failure,
  perform the appropriate AER commands on the guest. Right now that is
  a cop-out - we just kill the guest.

Besides implementing those commands, it can also

 - hide a PCI device from the host. When booting up, the user can specify
   xen-pciback.hide=(1:0:0)(BDF..) so that host does not try to use the
   device.

The driver was lifted from linux-2.6.18.hg tree and fixed up
so that it could compile under v3.0. Per suggestion from Jesse Barnes
moved the driver to drivers/xen/xen-pciback.

Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
Signed-off-by: Jeremy Fitzhardinge <jeremy.fitzhardinge@citrix.com>
2011-07-19 20:58:01 -04:00