Commit Graph

21 Commits (58287fd59c3c7b1f69715aefda888b0e1ccd68a3)

Author SHA1 Message Date
Kashyap, Desai 8ed9a03ad4 [SCSI] mpt2sas: removed use of tm_cmds.mutex in IOCTL branch.
Removed all the mutex's for ioc->tm_cmds.mutex, then created one
single mutex inside the function mpt2sas_scsih_issue_tm. This is the
single function used when sending task management. Also the sanity
checks required for scsi mid layer escalation were moved to inside the
same function because these checks need to be done while the mutex is
held. The ioc->tm_cmds.mutex inside the IOCTL branch is really not
required since there is another mutex in this code called for ctl_cmds
handling this sync.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2010-04-11 09:24:00 -05:00
Kashyap, Desai e94f674721 [SCSI] mpt2sas: Fix for little endian
1. Fixes for little endian issues.
2. Now Debug info for Discovery event is more readable.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2010-04-11 09:23:59 -05:00
Kashyap, Desai 22c88425e0 [SCSI] mpt2sas: Use compat_ptr to setup the pointer compatibility.
On ppc64, an 32bit application was failing due to data buffers not being
copied properly from user to kernel memory.  The problem due to improper
conversion of 32 to 64 bit pointers.  The fix is to use compat_ptr to
setup the pointer compatibility in the routine _ctl_compat_mpt_command.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Reviewed-by: Eric Moore <eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2010-02-08 18:19:40 -06:00
Kashyap, Desai b2ff36ba19 [SCSI] mpt2sas: Return -ENODATA on IOCTL timeout
The driver was modified to return -ENODATA when there is a timeout
via ioctl path.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Reviewed-by: Eric Moore <eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2010-02-08 18:19:38 -06:00
Kashyap, Desai 463217bfec [SCSI] mpt2sas : PPC (power pc) endian bug fix's
(1) EEDP(End to End data protection) was not working. This was due to not
setting EEDP BlockSize and Flags to little endian format in the message
frame.
(2) Some expander sysfs attributes were not getting set properly.  The sas
format was not getting set due to endian issues with sas_format field in the
struct rep_manu_reply. Since sas_format was not set properly, the
component_vendor_id, component_revision_id, and component_id were not set.
(3) In _transport_smp_handler: we don't need to convert the smid from little
endian to cpu prior to calling mpt2sas_base_free_smid, because its allready
in cpu format. (4) Some loginfos and ioc status were not xonverted from
little endian to cpu.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: Eric Moore <Eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2009-10-29 13:03:15 -04:00
Kashyap, Desai ec9472c74c [SCSI] mpt2sas: mpt2sas_base_get_sense_buffer_dma should be returning little endian
cpu_to_le64 when calculating the physical dma address. This will properly
handle endianess on big endian systems.  The return value of this function
was changed from dma_addr_t to __le64. Remove the typecasting of u32 when
setting the SenseBufferLowAddress, since its already in __le32 format.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: Eric Moore <Eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2009-10-29 13:03:14 -04:00
Kashyap, Desai 1b01fe3aa5 [SCSI] mpt2sas: Add Extended Type for Diagnostic Buffer support
Added tests for registry entries of EXBuffSize, EXImmed, and EXType to
support the new Extended diag buffer type.  Modified code where necessary to
handle the new ExtendedType field in the F/W diagnostic Post and Release
messages.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: Eric Moore <Eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2009-10-29 13:03:11 -04:00
Kashyap, Desai 32e0eb569d [SCSI] mpt2sas: Added command line option diag_buffer_enable.
Added command line option diag_buffer_enable. When the command line option is
set, the driver will automatically post diag buffers at driver load time.
The command line option diag_buffer_enable is bitwise, so it's possible to
enable both and/or snapshot + trace buffers.  For trace, the driver will
allocate 1MB buffer, whereas for snapshot its 2MB. The purpose for this is
so the enduser doesn't have to manually use an application to setup diag
buffers for debugging firmware related issues.

Here is some examples
trace:
# insmod mpt2sas.ko diag_buffer_enable=1

snapshot:
# insmod mpt2sas.ko diag_buffer_enable=2

both trace and snapshot:
# insmod mpt2sas.ko diag_buffer_enable=3

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: Eric Moore <Eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2009-10-29 13:03:11 -04:00
Kashyap, Desai fa7f316735 [SCSI] mpt2sas: Support for stopping driver when Firmware encounters
Added command line option and shost sysfs attribute called
mpt2sas_fwfault_debug. When enduser writes a "1" to this parameter, this
will enable support in the driver for debugging firmware timeout related
issues.  This handling was added in three areas (a) scsi error handling
callback called task_abort, (b) IOCTL interface, and (c) other timeouts that
result in diag resets, such as manufacturing config pages.  When this
support is enabled, the driver will provide dump_stack to console, halt
controller firmware, and panic driver. The end user probably would want to
setup serial console redirection so the dump stack can be seen.

Here are the three methods for enable this support:

(a) # insmod mpt2sas.ko mpt2sas_fwfault_debug=1
(b) # echo 1 > /sys/module/mpt2sas/parameters/mpt2sas_fwfault_debug
(c) # echo 1 > /sys/class/scsi_host/host#/fwfault_debug  (where # is
the host number)

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: Eric Moore <Eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2009-10-29 13:03:10 -04:00
Kashyap, Desai bcfb6e6ea4 [SCSI] mpt2sas: Call init_completion on a per request basis.
Now driver call init_completion on a per request basis.  At some
point the wait_for_completion_timeout is not waiting for the timeout,
instead returning immediately, thus going into diag reset.  This fix will
address all request using the wait_for_completion_timeout API. The previous
implimentation was only calling init_completion at driver
load time.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2009-10-02 09:48:50 -05:00
Kashyap, Desai 77e63ed443 [SCSI] mpt2sas: Target Reset will be issued from Interrupt context.
(1) Added three new functions to handle sending target resest and OP_REMOVE
from interrupt time, they are _scsih_tm_tr_send, _scsih_tm_tr_complete, and
_scsih_sas_control_complete.  This code will create a link list of pending
target resets if there is no more available request in the hipriority
request queue.  The list is stored in ioc->delayed_tr_list.

(2) All callback handler return type is changed from void to u8.
Now _base_interrupt will check for return type of callback handlers to
take decision of message frame is already freed or not.
In genral,
Return 1 meaning mf should be freed from _base_interrupt
       0 means the mf is freed from function.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2009-10-02 09:48:38 -05:00
Kashyap, Desai 595bb0bd62 [SCSI] mpt2sas: Added SCSIIO, Internal and high priority memory pools to support multiple TM
1) create a pool of high priority message frames in the region of memory
between message frames and chains.  The modifications are in
_base_allocate_memory_pools.  Also create a seperate pool of memory for
internal commands located near the same region of memory.  The pool of high
priority message frames is restriced by the facts->HighPriorityCredit.

2) Create additional API for accessing request message frames. New function
mpt2sas_base_get_smid_hpr is for highpriority request. New function
mpt2sas_base_get_smid_scsiio for SCSI_IO, passing in the scsi command
pointer.  The mpt2sas_base_get_smid function is for requesting internal
commands.

3) Added new function _base_get_cb_idx to obtain the callback
index from one of the three pools of request message frames.

4) Removed wrapper functions _scsih_scsi_lookup_set and
_scsih_scsi_lookup_getclear. These were removed because this handling was
moved into mpt2sas_base_get_smid_scsiio and mpt2sas_base_free_smid.

5) The function mpt2sas_base_free_smid is modified so the request message
frames are put back on one of the three pools of request message frames.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2009-10-02 09:48:26 -05:00
Kashyap, Desai 19d3ebe3d5 [SCSI] mpt2sas: Copyright change to 2009.
Update the copyright year to 2009 through out the code.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2009-10-02 09:48:15 -05:00
Kashyap, Desai 7b936b0229 [SCSI] mpt2sas: Update driver to MPI2 REV K headers.
Drivers header are updated to the MPI2 REV K headers.
Renamed VF_ID to msix_index in all call back handlers.
VF_ID is removed from all request descriptor.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2009-10-02 09:47:52 -05:00
Kashyap, Desai 155dd4c763 [SCSI] mpt2sas: Prevent sending command to FW while Host Reset
This patch renames the flag for indicating host reset from
ioc_reset_in_progress to shost_recovery. It also removes the spin locks
surrounding the setting of this flag, which are unnecessary.   Sanity checks on
the shost_recovery flag were added thru out the code so as to prevent sending
firmware commands during host reset.  Also, the setting of the shost state to
SHOST_RECOVERY was removed to prevent deadlocks, this is actually better
handled by the shost_recovery flag.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Reviewed-by: Eric Moore <Eric.moore@lsi.com>
Cc: Stable Tree <stable@kernel.org>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
2009-09-05 09:34:49 -05:00
Eric Moore ddf59a35e9 [SCSI] mpt2sas: add query task support for MPT2COMMAND ioctl
This patch will find an active mid for a query_task request via the ioctl path.

This code is already there for task_abort, so this patch combining code using
the same fuction _ctl_set_task_mid(), previously _ctl_do_task_abort().

Signed-off-by: Eric Moore <eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
2009-05-23 15:44:17 -05:00
Eric Moore 99bb214b1b [SCSI] mpt2sas : release diagnotic buffers prior host reset
Diagnostic buffer support is already there in the driver.  This support allows
applications to pull ring buffers from controller firmware for debugging
firmware related issues.

What this patch does is sends reqeust to firmware to release the buffers prior
to host reset.   This will allow what ever debug info is there prior to reset
to be dma'd to host memory. With out this fix, some of the debug data would
been lost.

Signed-off-by: Eric Moore <eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
2009-04-27 10:54:04 -05:00
Eric Moore e5f9bb198a [SCSI] mpt2sas : driver name needs to be in the MPT2IOCINFO ioctl
The driver name needs to be at the beginining of the driver_version string in
MPT2IOCINFO ioctl.  This is the same behaviour is there already in the mptsas
driver.

Signed-off-by: Eric Moore <eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
2009-04-27 10:53:58 -05:00
Eric Moore 77bdd9ee1e [SCSI] mpt2sas : running out of message frames
The driver is not freeing message frame when returning failure from
_ctl_do_task_abort.   If you call this function 500 times when its unable
to find an active task mid, you end up with no message frames.

Signed-off-by: Eric Moore <eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
2009-04-27 10:53:57 -05:00
Eric Moore ba33fadfab [SCSI] mpt2sas: make global symbols unique
The ioc_list global symbol is already used in 1st generation mpt
fusion drivers, so this patch makes it unique in the 2nd generation
driver.  I've checked the entire sources, and I don't see any other
global system missing the mpt2sas_xxx prefix.

Signed-off-by: Eric Moore <eric.moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
2009-03-17 21:52:46 -04:00
Eric Moore 635374e7eb [SCSI] mpt2sas v00.100.11.15
* This is new scsi lld device driver from LSI supporting the SAS 2.0
  standard. I have split patchs by filename.

* Here is list of new 6gb host controllers:

  LSI SAS2004
  LSI SAS2008
  LSI SAS2108
  LSI SAS2116

* Here are the changes in the 4th posting of this patch set:

(1) fix compile errors when SCSI_MPT2SAS_LOGGING is not enabled
(2) add mpt2sas to the SCSI Mid Layer Makefile
(3) append mpt2sas_ to the naming of all non-static functions
(4) fix oops for SMP_PASSTHRU
(5) doorbell algorithm imported changes from windows driver

* Here are the changes in the 3rd posting of this patch set:

(1) add readl following writel from the function that disables interrupts
(2) replace 0xFFFFFFFFFFFFFFFFULL with ~0ULL
(3) when calling pci_enable_msix, only pass one msix entry (instead of 15).
(4) remove the "current HW implementation uses..... " comment in the sources
(5) merged bug fix for SIGIO/POLLIN notifcation; reported by the storlib team.

* Here are the changes in the 2nd posting of this patch set:

(1) use little endian types in the mpi headers
(2) merged in bug fix's from inhouse drivers.

Signed-off-by: Eric Moore <eric.moore@lsi.com>
Tested-by: peter Bogdanovic <pbog@us.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
2009-03-13 16:08:49 -05:00