b53: Allow using all 8 ports on BCM53011

On two tested devices: Netgear R6250 (BCM53011 rev 2) and Luxul XWC-1000
(BCM53011 rev 3) it was possible to use port 7 and eth1 (instead of port
5 and eth0). It seems BCM53011 just like BCM53012 has 8 ports and
usually 3 of them are connected to the SoC.

Signed-off-by: Rafał Miłecki <zajec5@gmail.com>

Backport of r46104

git-svn-id: svn://svn.openwrt.org/openwrt/branches/chaos_calmer@46107 3c298f89-4303-0410-b956-a3cf2f4a3e73
zsun
rmilecki 2015-06-22 07:59:09 +00:00
parent 9e495194de
commit 45af270042
1 changed files with 1 additions and 1 deletions

View File

@ -1201,7 +1201,7 @@ static const struct b53_chip_data b53_switch_chips[] = {
.dev_name = "BCM53011",
.alias = "bcm53011",
.vlans = 4096,
.enabled_ports = 0x1f,
.enabled_ports = 0x1bf,
.cpu_port = B53_CPU_PORT_25, /* TODO: auto detect */
.vta_regs = B53_VTA_REGS,
.duplex_reg = B53_DUPLEX_STAT_GE,